Isovaleric Acid
How to detect Isovaleric Acid
Formula: | CAS:
Warning: array_chunk(): Size parameter expected to be greater than 0 in /www/wwwroot/ionscience/wp-content/themes/salient-child/wearegrid/vc-templates/vc-gas-pull-specification.php on line 156
Specification
Warning: Invalid argument supplied for foreach() in /www/wwwroot/ionscience/wp-content/themes/salient-child/wearegrid/vc-templates/vc-gas-pull-specification.php on line 160
View products detecting gaseous Isovaleric Acid
TVOC 2 Continuous VOC Gas Detector
TVOC 2 is a fixed, continuous VOC gas detector that accurately detects and measures Total Volatile Organic Compounds within industrial working environments.
Tiger Handheld VOC Gas Detector
The Tiger handheld VOC gas detector is a revolutionary portable PID instrument for rapid, accurate detection of volatile organic compounds (VOCs).
Tiger LT Portable VOC Gas Detector
The Tiger LT portable VOC gas detector is an entry-level, portable instrument for fast, accurate detection of volatile organic compounds (VOCs).
Cub 10.6 eV Personal VOC Gas Detector
Cub 10.6 eV personal VOC gas detector is worn within the breathing zone to detect volatile organic compounds, keeping you safe within your working environment.
PPM VOC Gas Sensor
Range: 0 to 4000 ppm. Minimum detection limit: 100 ppb. 10.6 eV lamp. The PPM VOC gas sensor - MiniPID 2 is designed for detecting VOCs over the widest dynamic range on the market without compromising performance.
PPB VOC Gas Sensor
Range: 0 to >40 ppm. Minimum detection limit: 1 ppb. 10.6 eV lamp. The PPB VOC gas sensor - MiniPID 2 is optimised to deliver an exceptionally low background which allows for optimum low-end sensitivity.
High Sensitivity VOC Gas Sensor
Range: 0 to 3 ppm. Minimum detection limit: 0.5 ppb. 10.6 eV lamp. The high sensitivity VOC gas sensor, is the highest sensitivity VOC gas sensor for sub PPB level detection.
11.7 eV VOC Gas Sensor
Range: 0 to >100 ppm. Minimum detection limit: 100 ppb. 11.7 eV lamp. The 11.7 eV VOC gas sensor lamp extends the range of detectable compounds, only available from ION Science.
10.0 eV VOC Gas Sensor
Range: 0 to >100 ppm. Minimum detection limit: 5 ppb. 10.0 eV lamp. The 10.0 eV VOC gas sensor - MiniPID 2 is used for enhanced selectivity of compounds with lower ionisation energies.
PPM WR VOC Gas Sensor
Range: >10,000 ppm. Minimum detection limit: 500 ppb. 10.6 eV lamp. The MiniPID PPM WR VOC gas sensor is designed for detecting VOCs over the widest dynamic range on the market without compromising performance.
PPB WR VOC Gas Sensor
Range: >200 ppm. Minimum detection limit: 20 ppb. The MiniPID 2 PPB Wide Range VOC gas sensor is optimised to deliver an exceptionally low background which allows for optimum low-end sensitivity.
GasCheck G Handheld Helium Gas Leak Detector
Designed for the search and location of gas leaks, the GasCheck G handheld helium gas leak detector provides you with effective detection of almost any gas or gas mixture.
GasClam 2 Continuous Ground Gas Detector
GasClam 2 continuous ground gas detector is a unique in-borehole gas monitoring system developed for the unattended collection of long-term gas data.
Falco Pumped – Fixed VOC Gas Monitor
Falco pumped instruments are ideal for detecting VOCs and TACs in difficult locations such as underground or in confined spaces.
Falco Diffused – Fixed VOC Gas Detector
Falco Diffused, Fixed VOC Gas Detector is ideal for detecting VOCs and TACs in areas such as refineries and petrol chemical facilities.
Sensor Development Kit (SDK)
Sensor Development Kit (SDK) for the integration of the MiniPID 2 photoionisation sensor.
Fire Investigation Kit
Tiger fire investigation kit provides fast, accurate detection of VOCs for fire and arson investigations with resistance to humidity and contamination.
GasCheck Tesla Portable Helium Leak Detector
ION Sciences portable helium leak detector is highly sensitive & effective for use within high magnetic fields.